The Automated Protection Devices Manufacturer!

 

Baoding Smail Electric Co., Ltd. was established on July 1, 2009 and is located in the National High-tech Industrial Development Zone of Baoding City, Hebei Province. It is a high-tech enterprise focusing on the research and development of power system automation, relay protection and instrumentation.

 

 
 

Why Choose Us

One-stop service

The company has a 3,600 square meter production base, with advanced production equipment and technical teams as well as R&D teams. It can customize products according to customer needs and strictly implement quality management systems to ensure product quality and production efficiency.

Production Market

Our products have won long-term trust and praise from customers such as State Grid, China Southern Power Grid, China Guoneng, China Huadian, State Power Investment Corporation, China Datang, China Huaneng and other major energy companies.

Certifications

It currently owns more than 20 patents and 18 software copyrights, and has passed ISO 9001 quality management system, ISO 14001 environmental management system and ISO 45001 occupational health and safety management system certification.

 

 

Our Company Offers The Following Products

 

Benefits of Arc Flash Protection Device
 
Arc Flash Protection Device

Protect the safety of the power system: Arc Flash Protection Device can detect the arc event in the circuit, and cut off the fault circuit within a few milliseconds, prevent the arc event from spreading, and protect the safety of the power system and workers. This can reduce the occurrence of power system accidents, reduce maintenance costs, and improve the reliability and stability of the power system.


Improve equipment life: Arc Flash Protection Device can avoid arc events in the circuit, reduce equipment wear and damage, and prolong equipment life. This reduces the cost of equipment repair and replacement and improves the operating efficiency of the power system.


Improve the efficiency of the power system: Arc Flash Protection Device can cut off the fault circuit in time to avoid energy loss and waste in the power system. This can improve the operating efficiency of the power system and reduce the energy consumption and cost of the power system.


Improve work efficiency: Arc Flash Protection Device can automatically detect arc events in the circuit, avoiding the tedious process of manual detection, improving work efficiency, and reducing the impact of human factors on the operation of the power system.


Realize intelligent management: Arc Flash Protection Device can be connected with other intelligent equipment such as protective equipment and a monitoring system to realize intelligent management of the power system.

 

Key Configuration And Setting Recommendations For Arc Flash Protection
 
Arc Flash Protection Device factory
 

Sensor Selection and Installation

Point Sensors: Simple installation, low cost, require reasonable planning of quantity to ensure coverage.
Fiber Optic Sensors: Large detection range, no dead angles, but slightly more complex installation and higher cost.
Absolutely avoid pointing sensors directly at the cabinet door viewing window, lighting, or other light sources.

 

Current Setting

Feeder Circuit: Iset should be greater than the load current but less than the minimum fault current. Typically can be set to > 1.2 I_load (load current).
Busbar Circuit: Iset should be set above the maximum load current and the current flowing through the busbar during a feeder fault, usually set to > 1.3 I_max (maximum load current).

Arc Flash Protection Device factory
Arc Flash Protection Device suppliers
 

Time Setting

Arc flash protection generally operates instantaneously, without time delay.
Ensure the inherent opening time of the relay and breaker itself is sufficiently short (total operation time ≤ 100ms).

 

Testing and Maintenance

A functional test must be performed before system commissioning, simulating an arc flash signal (using a dedicated test lamp) to verify the correctness of the sensors, logic, and trip circuit.
Conduct regular inspections to check if sensors are obstructed or contaminated.

Arc Flash Protection Device suppliers

 

The composition of zero sequence current transformer

Iron core

The iron core of a zero-sequence current transformer is usually made of silicon steel sheets. It has good magnetic permeability and low hysteresis loss, and can effectively conduct the magnetic field.


Primary winding

The primary winding is the main winding in the zero-sequence current transformer, through which the zero-sequence current to be measured flows. The primary winding usually consists of multiple strands of insulated wire to provide adequate current capacity and electrical insulation.

Secondary winding

The secondary winding is the auxiliary winding in the zero-sequence current transformer and is used to output a secondary current signal proportional to the primary current. The secondary winding usually consists of insulated wires wound around an iron core.

Insulation material

Insulation material is used to isolate the primary winding and secondary winding to ensure safe and reliable operation. Common insulation materials include insulating paper, insulating paint and insulating tape.

Enclosure

Zero-sequence current transformers are usually protected by an enclosure to provide mechanical strength and protection. The shell is usually made of insulating materials or metal materials with good heat resistance, corrosion resistance and insulation properties.

 

Zero sequence current transformer installation environment

 

The zero sequence current transformer should be installed in a humid environment to prevent corrosion and make the sensitivity decline, resulting in the protection device to refuse to move. If it must be installed in a humid environment, it should be installed in an airtight box to prevent rain and humid air from entering.

Zero sequence current transformer should avoid installation in high and low temperature environment. Because the temperature is too high or too low will affect the magnetic conductivity of the transformer, thus affecting the stability of the action.

Zero-sequence Current Transformer

 

Applications of Zero-sequence Current Transformer
 

Safety Protection

Prevents electric shock and electrical fires. Applications include: shopping malls, hotels, schools, residences, factories, and other densely populated or high-risk fire locations.

Zero-sequence Current Transformer factory
Zero-sequence Current Transformer suppliers

System Protection

Protects the power grid and equipment from grounding faults. Applications include: fires, equipment damage, electric shock, and leakage current circuit breakers.

Condition Monitoring

Provides early warning of insulation degradation, enabling predictive maintenance. Applications include: hospital operating rooms, chemical plants, and data centers.

Zero-sequence Current Transformer
Zero-sequence Current Transformer factory

Quality Analysis

Assists in power quality management. Applications include: Power quality monitoring systems, smart buildings, data centers, and industrial plants.

 

 

Packing Details

 

We will packing by professional export packing,safety against breakage, finally into the wooden cases/ carton/pallet or customized package.

 

productcate-948-390

 

Delivery Details

 

 

We can deliver by SEA,air,rail transportation,the China-Europe Railway Express etc.
TNT, DHL,UPS, FEDEX, EMS,S.F EXPRESS etc.

 

 

FAQ

 

Q: What is the function of zero phase current transformer?

A: Advanced zero-phase current transformers (ZCTs) represent a pivotal technology in the field of electronic components, particularly within the sensor domain. These devices are engineered to measure alternating current (AC) without the direct influence of voltage, enabling precise monitoring of electrical systems.

Q: Can I buy samples placing orders?

A: Yes.Please feel free to contact us.

Q: What is your lead time?

A: It depends on the order quantity and the season you place the order. Usually we can ship within 7-15 days for small quantity,and about 30 days for large quantity.

Q: What is your payment term?

A: T/T,Western Union,Alipay,MoneyGram,and Paypal.This is negotiable.

Q: What is the shipping method?

A: It could be shipped by sea,by air or by express(EMS,UPS,DHL,TNT,FEDEX and ect).Please confirm with us before placing orders.

We are one of the most professional automated protection devices manufacturers in China, also support customized service. Please rest assured to buy high quality automated protection devices at low price from our factory. If you have any enquiry about samples, please feel free to email us.

Low current grounding fault location, Arc Flash Protection Device, Small Current Grounding Fault Location Device
Send Inquiry