Product Overview
The medium-voltage switchgear for plant/distribution systems serves as the power supply hub for the entire plant's auxiliary equipment/power supply system. The ability to quickly isolate faults during internal failures is crucial for the safe operation of the entire plant/distribution system. However, current protection schemes have the following problems:
1) The medium-voltage busbar lacks dedicated protection; it is instead handled by the backup protection of the incoming line switches.
2) The protection of the incoming and outgoing line switches requires coordination: the delay difference for instantaneous overcurrent protection is generally at least 300ms, or even 500ms.
3) The coordination difference for overcurrent protection is even longer, reaching 1-2 seconds.
Therefore, any fault occurring on the medium-voltage busbar in the plant/distribution system must be isolated with at least a delay. In other words, the existing protection for the plant's medium-voltage busbar to isolate faults immediately is lacking. However, with a little attention, it is easy to see that numerous electrical devices upstream and downstream of the medium-voltage switchgear busbar are equipped with fast-acting protection. In contrast, we would find it difficult to justify such negligence regarding the safety and reliability of medium-voltage busbars. Given the critical role of medium-voltage busbars, any delayed fault clearing is an extremely undesirable situation. Various faults within the switchgear cause the arc generated by the short-circuit current and its resulting high temperature, leading to a rapid expansion of the gas inside the cabinet, reaching its peak in a very short time, seriously endangering personal and equipment safety.
Product Features
1) Fast tripping output for the entire unit;
2) Reliable operation using overcurrent and arc flash as criteria;
3) Continuous and comprehensive self-testing function;
4) Flexible programming for various wiring configurations;
5) Simple and flexible installation.
Our Honors
Baoding Simaier Electric Co., Ltd. has been awarded numerous honors, including National High-tech Enterprise, National Science and Technology-based SME, and Provincial Science and Technology-based SME. It has been rated as an AAA-level credit enterprise and is a large-scale enterprise. Currently, it holds over 20 patents and 18 software copyrights, and has passed ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 45001 Occupational Health and Safety Management System certifications. Our products have earned the long-term trust and praise of customers such as State Grid, China Southern Power Grid, China Guoneng, China Huadian, State Power Investment Corporation, China Datang, China Huaneng, and other major energy companies. They are also exported to many countries and regions overseas.
Hot Tags: arc flash protection device, China arc flash protection device manufacturers, Arc Flash Protection Device, Distributed Grounding Fault Tripping Device, High precision Zero sequence Current Transformer, High voltage Anti islanding Protection Device, Low current grounding fault location, Reverse power protection equipment