Transformer Neutral Point Gap Grounding Protection Complete Set Device

Send Inquiry
Transformer Neutral Point Gap Grounding Protection Complete Set Device
Details
Our company's SMR-ZJB series transformer neutral point gap grounding protection device is a specialized complete set of equipment for overvoltage protection of the neutral point of 110kV/220kV transformers.
Category
Neutral Point Grounding
Share to
Description

Product Overview

 

Our company's SMR-ZJB series transformer neutral point gap grounding protection device is a specialized complete set of equipment for overvoltage protection of the neutral point of 110kV/220kV transformers. The entire set of equipment uses the SMR-ZJB series transformer neutral point protection gap as its core, and is equipped with disconnecting switches and surge arresters according to the operating environment and user requirements. Typical application schemes include: a combination scheme of disconnecting switch and surge arrester discharge gap, a combination scheme of disconnecting switch and discharge gap, and a pure gap scheme.

 

Product Features

 

The SMR-ZJB series transformer neutral point protection gap is manufactured according to the relevant provisions of DL/T-620-1997 "Overvoltage Protection and Insulation Coordination of AC Electrical Installations" regarding the use of gap protection for the neutral point of transformers in 110kV and 220kV effectively grounded power networks, and is designed with reference to the technical requirements for neutral point protection gaps in "25 Key Requirements for Preventing Major Accidents in Power Production" published by the State Grid Corporation's Transmission and Power Operation Department in September 2000.

 

Product Structure and Composition

 

This complete set of equipment is a modular unit, mainly comprising the following components:

Disconnecting Switch: Used to connect or disconnect the grounding connection of the transformer neutral point, facilitating equipment maintenance and changes in operating mode.

Zinc Oxide Surge Arrester: The core voltage-limiting element, used to limit various overvoltages.

Discharge Gap: Consists of two rod-shaped electrodes; the gap distance can be precisely adjusted according to the system voltage, and is crucial for achieving gap protection.

Current Transformer: Installed in the neutral point circuit, used to collect zero-sequence current, providing operating signals for the protection device.

Supporting Insulators and Steel Structure Brackets: Provide robust mechanical support and reliable electrical insulation for all equipment.

 

Our Advantages

 

The company has won many honors such as National High-tech Enterprise, National Science and Technology Small and Medium-sized Enterprise, Provincial Science and Technology Small and Medium-sized Enterprise, and has been rated as an AAA credit rating and a large-scale enterprise. It currently owns more than 20 patents and 18 software copyrights, and has passed ISO 9001 quality management system, ISO 14001 environmental management system and ISO 45001 occupational health and safety management system certification.

 

FAQ

 

Q: How is the gap distance determined?

A: The gap distance is precisely calculated and set by the power design institute based on system parameters to ensure effective protection without malfunction. On-site adjustments are strictly prohibited.

Q: Why do surge arresters sometimes explode?

A: Surge arrester explosions are usually due to:
Intrinsic quality defects: internal moisture or aging of the valve plates.
Experiencing overvoltages beyond its energy capacity: for example, prolonged power frequency overvoltages exceeding its withstand capability. In this case, if the gap alignment is incorrect, the surge arrester may bear the load that should have been applied by the gap, easily leading to overheating and explosion.

 

Hot Tags: transformer neutral point gap grounding protection complete set device, China transformer neutral point gap grounding protection complete set device manufacturers, Primary harmonic suppressor, Neutral point complete set of equipment, Grounding transformer and low resistance complete set of equipment, Grounding transformer and station service transformer set, Small resistance grounding complete set of equipment, Arc suppression coil

Send Inquiry